Theses and Dissertations (Civil Engineering)
Permanent URI for this collection
Browse
Browsing Theses and Dissertations (Civil Engineering) by Author "Ndambuki, J. M., Prof."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Effect of land-use change on traffic peak hour factor(Vaal University of Technology, 2012-01) Phahlane, Motsepe Herbert; Salim, W. R., Dr.; Ndambuki, J. M., Prof.Growth in land development in South Africa resulted in large increase in traffic volumes. A Traffic Impact Assessment (TIA), as a traffic engineering tool, is commonly used to assess the possible effects of a land development project on the transportation and traffic system. During the TIA process, capacity analysis is performed to indicate the measures of effectiveness of the intersection. Intersection capacity analysis in South Africa by engineers is done on the basis of default values of the Peak Hour Factor (PHF) provided by the Highway Capacity Manual (HCM) or limited traffic counts. However, the default value of PHF may be significantly affected by new developments in the neighbourhood of the intersection. This study aimed at investigating the impact land-use change has on the existing intersection PHF, thus predicting values per land-use type. Intersections with traffic counts conducted before and after land-use change in vicinity were selected and investigated. The results showed that change in land-use has an impact on the existing PHF. They also assist in identifying the appropriate intersections to predict the PHF per land-use type. Intersections were identified and analysed, and this led to the development of a design chart showing the predicted PHF per land-use type selected and measures to consider during traffic analysis. Intersection capacity analysis was performed to compare the results using the predicted PHF and the HCM default values. The results showed that traffic flow rate was adjusted by up to 26% when using the default values, 0.92 and 0.95. The results also showed that the default values could overestimate the volume to capacity ratio and the average delay by up to 15% and 35%, respectively. It was then concluded that the use of HCM default values of the PHF for every land-use type will have an effect of the final roadway design results. The computed PHF values for each land-use type were then recommended to be used to ensure fairness and consistency in traffic analysis.Item Monitoring and modelling of water quality characteristics along a reticulation system: a case study of modimolle reticulation network(2012-01) Mehlo, Mahlomola; Wanjala, R. Salim, Dr.; Ndambuki, J. M., Prof.Potable water quality can deteriorate immensely from point of treatment to point of usage. This change in quality along a bulk distribution main may be attributed to numerous factors, such as the ingress of storm water. Furthermore, water utilities experience challenges in terms of the microbiological organisms that are not attributed to operational practices. For example, drinking water bulk distribution mains may be a shelter for these microorganisms that are sustained by organic and inorganic nutrients present within the pipe itself. These microorganisms may be active in the water being transported by the pipe, and can cause a significant drop in the water quality. In order to deal with the problem of deteriorating water quality, sufficient information within the bulk main is required, so that the consumer can be protected from ingesting contaminated water or water of poor quality. Hence, the overall objective of this study was to investigate and model water quality characteristics within the Modimolle reticulation network. Water samples were collected from various points throughout the entire system for quality analysis. Different sampling points were established along the main pipeline as well as within the Modimolle distribution system. Water quality software, EPANET, was then used to model the water quality deterioration for both the bulk line and the reticulation network of Modimolle extension 11. Residual chlorine was the main parameter which was monitored. This study presents results of a research on water quality variation within a long distribution mains conveying water up to 87 km. Results show that raw residual chlorine is constantly depleted along the pipeline, and is therefore unable to be maintained at the required level of 0.2 mg/l, as stipulated by the Department of Water Affairs. This means that if any harmful contaminants should enter the water, the residual chlorine in the water will not be able to protect the consumers from the contaminants.